Application and Study on the New Alveolate Primary Air Gauge

LI Jian,XIONG Jian-Guo,FANG Lei,HUANG Yu-ming
2010-01-01
Abstract:New alveolate primary air flow meter is designed based on the principles of commutation and segmented section measurement in view of the difficulties to measure the primary air flow at coal pulverizer inlet because of the complex structure and the compact layout of primary air duct in power plants. And it is applicable to air flow measurement for large-scale complicated cross section well. The deviation of air flow measurement of this type of device is less than 5% and meets the requirement of precision and can also match the changes of air valves.