Abstract:The corona onset voltage is an important parameter to reflect conductor's corona characteristics,therefore,the onset voltage of some different types and surface conductors were measured in the small corona cage used in the laboratory.The existed onset voltage measurement methods cannot distinguish the partial onset voltage and the overall onset voltage of transmission line.The process of corona onset and development was analyzed to present the current coefficient method which was used to estimate the onset voltage of DC conductors,and results of different methods were compared.Based on the experimental results,the corona impulse method and current coefficient method were recommended to measure the partial onset voltage and onset voltage of DC conductors in the corona cage respectively.