Measurement of Positive Direct Current Corona Pulse in Coaxial Wire-Cylinder Gap

Han Yin,Bo Zhang,Jinliang He,Wenzhuo Wang
DOI: https://doi.org/10.1063/1.4868966
IF: 2.2
2014-01-01
Physics of Plasmas
Abstract:In this paper, a system is designed and developed to measure the positive corona current in coaxial wire-cylinder gaps. The characteristic parameters of corona current pulses, such as the amplitude, rise time, half-wave time, and repetition frequency, are statistically analyzed and a new set of empirical formulas are derived by numerical fitting. The influence of space charges on corona currents is tested by using three corona cages with different radii. A numerical method is used to solve a simplified ion-flow model to explain the influence of space charges. Based on the statistical results, a stochastic model is developed to simulate the corona pulse trains. And this model is verified by comparing the simulated frequency-domain responses with the measured ones.
What problem does this paper attempt to address?