Measurements of Flow Field in Wire-plate Electrostatic Precipitator During Positive or Negative Corona Discharge Using PIV Method

Xinjun SHEN,Yuxuan ZENG,Qinzhen ZHENG,Keping YAN
DOI: https://doi.org/10.13336/j.1003-6520.hve.2014.09.021
2014-01-01
Abstract:In electrostatic precipitators(ESPs), the variation of flow field greatly affects the capture of fine particles. Therefore, we measured the flow field in a wire-plate ESP model using particle image velocimetry(PIV). The ESP model has side-walls made of acrylic, and two discharge electrodes made of two stainless-steel circle wires with adjustable spacing. We used moxa-moxibustion smoke as tracer particles, and the smoke's primary flow velocity was about 0.5 m/s. The observation plane of flow field was placed perpendicular to the central line between the discharge electrodes and the dust collecting electrodes. We applied either positive or negative DC high voltages in the experiments. The results show that the primary flow velocity increases with the applied voltage, and the maximum velocity increments reache 0.6 m/s and 0.7 m/s due to the ionic wind generated by the positive and negative corona discharge, respectively. When the applied voltage is about ±30 kV, there are four vortexes between the two discharge electrodes. The higher the applied voltage is, the more evenly and symmetrically the four vortexes distribute. Moreover, wider discharge electrodes spacing helps to generate the four vortexes. The vortexes seriously weaken the ESP model's capture efficiency of fine particles.
What problem does this paper attempt to address?