Analytical Method for Particle Collection in a High-temperature Wire-cylinder Electrostatic Precipitator

Xihui WANG,Houtao CHEN,Guang YANG,Gang XIAO
DOI: https://doi.org/10.3969/j.issn.1674-7607.2018.04.009
2018-01-01
Abstract:By analyzing the force condition of charged particles in gas flow field coupled with electric field,the particle trajectory in effective collection space was calculated,so as to derive the formula for collection efficiency of particles.Results show that the calculation results agree well with experimental data at the temperature of 350-700 ℃ with port voltage greater than 15 900 V,when the maximum relative error is less than 9 %.The boundary effect of cathode line should be considered in the case of mean gas velocity being larger than 0.2 m/s.For particles with same diameter,the migration velocities differ a lot when their initial positions are different in the electric field.The required height of precipitator reduces with the rise of port voltage;taking the particle of size 10 μm as an example,to reach the collection efficiency of 100% at the temperature of 620 ℃,the required height is about 0.86 m for a port voltage of 15 925 V,which is about 0.42 m when the port voltage gets up to 19 200 V.A particle is more likely to be captured when entering the electric field,if its initial position is in the vicinity of cathode line or anodic tube.
What problem does this paper attempt to address?