Particle collection in wire-plate electrostatic precipitators at high temperature

Xi XU,Dian XU,Pei YAN,Wei-zhuo ZHU,Cheng-hang ZHENG,Xiang GAO,Zhong-yang LUO,Ming-jiang NI,Ke-fa CEN
DOI: https://doi.org/10.3785/j.issn.1008-973X.2017.03.008
2017-01-01
Abstract:An experimental-scale wire-plate electrostatic precipitator (ESP) system at high temperature was built to investigate the behaviors of corona discharge,particle migration and particle collection from 400 ℃ up to 700 ℃.The Influence rule was explored that of temperature,applied voltage and gas velocity on particle collection and particle migration velocity.The mechanism of temperature variation on corona discharge and particle collection was discussed.The increase of temperature affects the mean free path of electrons,the ionization energy of the gas molecules,particle charge,Coulomb force and viscous force of particle,leading to the decrease of applied voltage,particle collection efficiency and particle migration velocity.When temperature increases from 400 ℃ to 700 ℃,the applied voltage decreases from 21.9 kV to 14.3 kV,the particle collection efficiency decreases from 98.1% to 68.2%,and the particle migration velocity decreases from 8.54 cm/s to 2.45 cm/s.The influence of temperature on particle efficiency is more obvious at high temperature than that at low temperature.As the gas velocity increases,the particle collection efficiency decreases,but the particle migration velocity increases.When the gas velocity increases from0.15 m/s to 0.35 m/s at 700 ℃,the particle collection efficiency decreases from 81.2% to 64.5%,but the particle migration velocity increases from 1.79 cm/s to 2.59 cm/s.