Welding Effects on Roof Closure Process of Shenzhen-wan Stadium

Guo Yanlin,Zhao Siyuan
2011-01-01
Abstract:High residual stresses of members will lead to residual internal force and deformation in the structures when the member-welding is constrained by around members.This additional residual internal force in the structure may result in structural member yielding due to compression or cracking due to tension.The authors focuse on the effect of roof welding closure process of Shenzhen-wan Stadium.Welding shrinkage deformation of a single tube is studied firstly,and a proposed formula for predicting welding shrinkage deformation is drawn.Then a typical H-shaped frame model is proposed to investigate the effect of welding size and welding sequence of a single beam due to the constraint provided by adjacent members.The conclusion is drawn and is used in the roof welding closure process of Shenzhen-wan Stadium based on the equal welding deformation principle.Simulating results of the roof closure process indicate that internal force of tubes in the nearby welding path due to welding shrinkage cannot be ignored.
What problem does this paper attempt to address?