Stability analysis of roof structure of Zhejiang University Zijingang Gymnasium

Deng Hua,Jiang Xudong,Yuan Xingfei,Shen Jin,Dong Shilin,Qiu Tao
DOI: https://doi.org/10.19701/j.jzjg.2013.15.010
2013-01-01
Abstract:A new roof structure consisting of cable-mast tensile system and its suspended rigid reticulated structure is adopted in Zhejiang University Zijingang Gymnasium.The structural characteristics and design outlines of this roof structure are introduced.Structural stability under three typical load cases is analyzed according to the method suggested in China Code.The critical load-bearing capacities affected by the mode of initial imperfection and its magnitude as well as the axial stiffness of roof bracing members are further investigated.The results indicate that the roof structure maintains higher critical load-bearing capacity in NS half-span load case,but significant decreases occur in full-span and EW half-span load cases.The structural critical load-bearing capacity varies very limitedly with the mode of initial imperfection for all three load cases,however it is sensitive to the magnitude of initial imperfection for NS half-span load case.Over-increasing the stiffness of bracing members may decrease the stability of this roof structure instead.
What problem does this paper attempt to address?