Space-Adjustable Non-Contact 3-Electrode Method for Thin Film Measurement

Liu Ying,Cao Xiaolong
2007-01-01
Abstract:The space-adjustable non-contact 3-electrode method is recommended by IEC for εr and tanδ measurement of insulating films. According to the national standard to be pushed, a high precision, air-medium, space-adjustable, non-contact, 3-electrode system is developed in the paper, and the measuring electrode is 38mm in diameter and the guard gap is 0.2mm in width. This electrode is specially designed for films thinner than 30μm, and it is proven that the measuring error of εr can be less than 5% and the order of tanδ reaches 10?5. The key influencing factors are systematically researched in this paper through experiments and theoretical analyses. At the end, the two non-contact methods are compared for proper applicability.