In-situ measurement of Cu film thickness during the CMP process by using eddy current method alone

Zilian Qu,Qian Zhao,Yonggang Meng,Tongqing Wang,Dewen Zhao,Yanwu Men,Xinchun Lu
DOI: https://doi.org/10.1016/j.mee.2013.03.046
IF: 2.3
2013-01-01
Microelectronic Engineering
Abstract:n eddy current measurement system for Cu thickness in CMP was established.The nano-scale sensitivity under large lift-off distance was reached by optimizing.The differential method for signal processing avoids the drift of system. A fast, accurate and in situ method for determination of interconnect Cu film thickness in the range from 200 to 500nm is a crucial requirement in the stress free polishing (SFP) process which is a novel semiconductor manufacture technique. This paper presents an in situ Cu film thickness measurement system with an optimized eddy current transducer for this purpose. The fabricated transducer has been integrated into a chemical mechanical polishing (CMP) platform for the purpose of testing. Measurement tests for both the Cu film with uniform thickness and the Cu film with interconnects are conducted. The CMP experiment results show that the resolution of the transducer can achieve a few nanometers under 3mm lift-off distance. With the increase in the density of the underlying Cu interconnects, the measured thickness value of the overlaid Cu film is also increased. By using an on-line differential signal processing method, the drift of the measurement system is removed. The repeatability and instability errors are less than 1.6%. The system can meet the technical requirements for advanced CMP processes.
What problem does this paper attempt to address?