Durability of FRP bars exposed to alkaline corrosion environment

Wang wei,Meng Yanling,Qian Wenjun
DOI: https://doi.org/10.3969/j.issn.1002-1396.2009.02.008
2009-01-01
Abstract:Accelerated aging tests of glass fiber reinforced polymer(GFRP) bars and carbon fiber composite cable (CFCC) bars were exposed to alkali solutions at 60℃for examining their durability.The results reveal that the ultimate tensile strength and elastic modulus of the GFRP bars lowers by 38.6%and 6.6%respectively after being immersed in alkali solution with pH of 13 at 60℃for 54 days.However,there is no any pitting corrosion phenomenon occurred on surface of the CFCC bars and furthermore,their elastic modulus even increase 12% after undergoing the identical treatment for 54 days,this fact accounts for the decline tendency in ductibility of the bars.The CFCC bars have the advantage over GFRP bars in alkali resistance.
What problem does this paper attempt to address?