Effect of sustained loads on the durability of GFRP bars with and without UHP-ECC cover

Zhi-Hao Hao,Jun-Jie Zeng
DOI: https://doi.org/10.1016/j.engstruct.2024.118050
IF: 5.582
2024-04-24
Engineering Structures
Abstract:Fiber-reinforced polymer (FRP) bar reinforced ultra high-performance engineered cementitious composite (UHP-ECC) structures (referred to as FRP-UHP-ECC structures) have been demonstrated to have excellent mechanical properties, while their durability in the alkaline environment has never been explored, particularly when being subjected to tensile loadings. To this end, this article aims to investigate the effects of sustained loads on the durability performance of Glass FRP (GFRP) bars embedded in UHP-ECCs while immersed in an alkaline solution. The test results revealed that the effect of elevated temperatures was exacerbated when specimens were subjected to even a low sustained load (20 % of ultimate strength). Furthermore, UHP-ECC covers considerably postponed the degradation of GFRP bars. Nevertheless, the protective effects of UHP-ECC covers were nearly entirely compromised when the specimens were subjected to sustained loads. The findings of this study provide useful knowledge for a comprehensive evaluation of the durability of GFRP bars under UHP-ECC environments.
engineering, civil
What problem does this paper attempt to address?