Analysis of the Applicability of a Phase-Change Energy Storage Wall for Public Buildings in Hot Summer and Cold Winter Climate Zones

Haowei Hu,Yubin Zhang,Qin Li,Taotao Shui,Jing He
DOI: https://doi.org/10.1080/01457632.2024.2400867
IF: 2.3
2024-09-15
Heat Transfer Engineering
Abstract:The effects of applying a phase-change energy storage wall in office buildings in hot summer and cold winter climate zones were analyzed by comparing several factors based on numerical calculations, specifically focusing on the internal and external wall temperature, delay time, attenuation multiple, and building load. It was found that the most effective phase-change temperature was 30 °C and the optimal thickness for the phase-change layer was 30 mm. The adoption of the outer phase-change wall layout improved the heat insulation performance during the summer. This effectively enhanced the energy-saving effect of the phase-change layer thickness and layout, which aligns with the influence law of phase-change wall heat transfer.
engineering, mechanical,thermodynamics,mechanics
What problem does this paper attempt to address?