Numerical Study on Wall Insulation Construction Affecting the Energy Consumption under the Intermittent and Loculose Energy Use

Yao-tai ZHU,Yi-lun ZHANG,Min-li WU,Xiao-qian QIAN
DOI: https://doi.org/10.3969/j.issn.1673-7237.2014.02.011
2014-01-01
Abstract:For characteristics of intermittent and loculose energy use in hot summer and cold winter zone, the software DeST was adopted for hourly dynamic simulation analysis for the summer cooling energy consumption of different interior and outer structure systems. Then the software Fluent was adopted for dy-namic simulation analysis by seconds for the enclosure structure’s surface temperature and heat flow within 10~14 days. The results show that the energy-saving rate is less than 5% in hot summer and cold winter zone when only outer wall is in exterior insulation, but if the outer and interior walls are all in the internal thermal insulation, the energy-saving rate will be greatly improved. Under the condition of unsteady, wall temperature fluctuation is far less than the outdoor environment temperature, and the range of maximum and minimum temperature is only 2~3℃, besides the range will be smaller only to 0.5 ℃or so if using ex-ternal thermal insulation. The air conditioning energy consumption differences with different retaining structures mainly reflected as the size of heat flux on the interior surface of the wall. Base on the intermit-tent and loculose energy use characteristics in hot summer and cold winter zone, the heat flux dissipated on interior wall are the main part.