Influence on energy saving effects of internal and external wall insulations for different occupant behaviors

Fang RUAN,Xiaoqian QIAN,Kuangliang QIAN,Xin FU
DOI: https://doi.org/10.11918/j.issn.0367-6234.2017.02.018
2017-01-01
Abstract:Aiming at the problem of serious deviation from the actual energy consumption for the calculated energy consumption with the continuous operation mode prescribed in current design standard for residential building energy efficiency in hot summer and cold winter zone, a questionnaire survey for the use mode of air conditioner has been conducted in Hangzhou, a typical city in this climate zone. It was found that there widely exists intermittent energy consuming method in the residential buildings of this area. The air conditioning using behavior was affected by thermal feeling of human body. The greater the indoor air temperature deviates from the the human body comfort scope, the higher the air conditioning opening rate is. DeST was employed to calculate the annual energy consumption of the residential building with internal and external wall insulations under different occupant behaviors, and then the annual energy saving effects were analyzed. The results show that in continuous energy consuming method, the annual energy saving effect for external insulation is better than that for internal insulation;in intermittent energy consuming method without considering tolerate temperature, the annual energy saving effect for internal insulation is better than that for external insulation. Under the condition of variable tolerate temperature, the critical tolerate temperature point for internal and external insulation with the same energy saving effect is 31.8 ℃ in summer and 13.4 ℃ in winter. When tolerate temperature is lower than the critical point, the internal insulation has better energy saving effect; when tolerate temperature is higher than the critical point, the external insulation has better energy saving effect. The choice of reasonable insulation means in this region was greatly affected by the air?conditioning behaviors and occupants’ thermal tolerance. The critical tolerate temperature for the same energy saving of the internal and external insulations is 31.8℃ in summer and 13.4℃ in winter. Therefore, setting reasonable air?conditioning behavior in the design standard for energy efficiency is an important premise for accurately evaluating the energy saving effect of exterior wall insulation measures.
What problem does this paper attempt to address?