Anti-insulation Behavior for Exterior Wall External Insulation on Residential Buildings in Hot Summer and Cold Winter Zone

RUAN Fang,QIAN Xiao-qian,QIAN Kuang-liang,YU Ya-chao,SHI Shui-hua
DOI: https://doi.org/10.3785/j.issn.1008-973x.2016.12.014
2016-01-01
Abstract:The EnergyPlus simulation software was employed to analyze the energy saving effect of exterior wall external insulation in residential building of the hot summer and cold winter zone . Hangzhou was taken for an example to address the problem of the discrepancy between the actual air conditioning (AC) working conditions and design conditions in standards for residential building energy efficiency in this region .Results show that under the standard way of continuous AC operation method ,exterior insulation has good energy saving effect ;however ,under intermittent AC operation method ,external insulation can increase the annual cooling load .Based on daily meteorological data from 1971 to 2000 , the five days moving average method was adopted to obtain the recommended value of heating and cooling period ,which is more accordant with the actual situation of Hangzhou .After using the new heating and cooling period , the influence of anti-insulation behavior for exterior insulation on annual energy consumption is more significant ;the annual energy saving rate significantly reduced . Further research shows that for the window to wall ratio (WWR) and cooling set temperature ,there are a series of critical value for anti-insulation behavior in summer cooling (0 .3 for WWR and 26 ℃ for cooling set temperature) .When WWR and cooling set temperature are lower than the critical value ,external insulation saves energy ;when WWR and cooling set temperature are higher than the critical value ,total energy consumption increases .
What problem does this paper attempt to address?