The design and performance of the XL-Calibur anticoincidence shield
N. K. Iyer,M. Kiss,M. Pearce,T. -A. Stana,H. Awaki,R. G. Bose,A. Dasgupta,G. De Geronimo,E. Gau,T. Hakamata,M. Ishida,K. Ishiwata,W. Kamogawa,F. Kislat,T. Kitaguchi,H. Krawczynski,L. Lisalda,Y. Maeda,H. Matsumoto,A. Miyamoto,T. Miyazawa,T. Mizuno,B. F. Rauch,N. Rodriguez Cavero,N. Sakamoto,J. Sato,S. Spooner,H. Takahashi,M. Takeo,T. Tamagawa,Y. Uchida,A. T. West,K. Wimalasena,M. Yoshimoto
DOI: https://doi.org/10.1016/j.nima.2022.167975
2022-12-08
Abstract:The XL-Calibur balloon-borne hard X-ray polarimetry mission comprises a Compton-scattering polarimeter placed at the focal point of an X-ray mirror. The polarimeter is housed within a BGO anticoincidence shield, which is needed to mitigate the considerable background radiation present at the observation altitude of ~40 km. This paper details the design, construction and testing of the anticoincidence shield, as well as the performance measured during the week-long maiden flight from Esrange Space Centre to the Canadian Northwest Territories in July 2022. The in-flight performance of the shield followed design expectations, with a veto threshold <100 keV and a measured background rate of ~0.5 Hz (20-40 keV). This is compatible with the scientific goals of the mission, where %-level minimum detectable polarisation is sought for a Hz-level source rate.
Instrumentation and Methods for Astrophysics,Instrumentation and Detectors