CZT imaging detectors for ProtoEXIST

J. Hong,J. E. Grindlay,N. Chammas,A. Copete,R. G. Baker,S. D. Barthelmy,N. Gehrels,W. R. Cook,J. A. Burnham,F. A. Harrison,J. Collins,W. W. Craig
DOI: https://doi.org/10.1117/12.680721
2006-09-01
Abstract:We describe the detector development for a balloon-borne wide-field hard X-ray (20 - 600 keV) telescope, ProtoEXIST. ProtoEXIST is a pathfinder for both technology and science of the proposed implementation of the Black Hole Finder Probe, Energetic X-ray Imaging Survey telescope (EXIST). The principal technology challenge is the development of large area, close-tiled modules of imaging CZT detectors (1000 cm2 for ProtoEXIST1). We review the updates of the detector design and package concept for ProtoEXIST1 and report the current development status of the CZT detectors, using calibration results of our basic detector unit - 2 x 2 x 0.5 cm CZT crystals with 2.5 mm pixels (8 x 8 array). The current prototype (Rev1) of our detector crystal unit (DCU) shows ~4.5 keV electronics noise (FWHM), and the radiation measurements show the energy resolution (FWHM) of the units is 4.7 keV (7.9%) at 59.5 keV, 5.6 keV (4.6%) at 122 keV, and 7.6 keV (2.1%) at 356 keV. The new (Rev2) DCU with revised design is expected to improve the resolution by ~30%.
Astrophysics
What problem does this paper attempt to address?
The main problem that this paper attempts to solve is how to develop and optimize large - area, closely - packed CZT (cadmium - zinc - telluride) imaging detector modules for the hard X - ray telescope ProtoEXIST. Specifically, the paper focuses on the following aspects: 1. **Development of large - area detector arrays**: ProtoEXIST aims to realize a wide - field - of - view hard X - ray (20 – 600 keV) telescope, especially as a pathfinder for the Energetic X - ray Imaging Survey Telescope (EXIST). The main technical challenge is to develop large - area (e.g., 1000 cm²), closely - packed CZT detector modules. 2. **Improving energy resolution and reducing noise**: The paper describes in detail how to improve energy resolution and reduce electronic noise by improving the detector design and packaging concept. For example, the detector crystal unit (DCU) of the current prototype (Rev1) shows an electronic noise (FWHM) of about 4.5 keV, while the newly - designed Rev2 DCU is expected to improve the resolution by about 30%. 3. **Multi - pixel pulse profile readout**: Multi - pixel readout and pulse profile sampling are achieved using RadNet ASICs, which are very important for handling charge - splitting events and Compton scattering. In addition, the pulse profile information can be used for depth perception and correction of incomplete charge collection. 4. **Low - power consumption requirements**: Due to limited resources in space missions, the detector needs to operate at a power consumption of < 100 μW per pixel. Therefore, the selection and optimization of low - power ASICs are specially considered in the design. 5. **Optimization of data readout modes**: To deal with the dead - time limitations at high count rates, the paper explores multiple data readout modes, including debug mode, variable mode, normal mode, complete mode, and calibration mode, in order to find the most efficient and useful data acquisition methods. ### Summary The core problem of this paper is to develop a high - performance, large - area CZT detector array for hard X - ray astronomical observations, especially in the ProtoEXIST project. By optimizing the detector design, reducing noise, improving energy resolution, and optimizing the data readout mode, the research team hopes to provide key technical verification and support for future space missions (such as EXIST). If you have more specific questions or need further explanation, please feel free to ask!