Feasibility of using 3D CZT drift strip detectors for small Compton camera space missions

S.R.H. Owe,I. Kuvvetli,A. Zoglauer,C. Budtz-Jørgensen
DOI: https://doi.org/10.1088/1748-0221/19/01/c01005
2024-01-06
Journal of Instrumentation
Abstract:This feasibility study explores the possibility of using 3D CZT drift strip detectors developed by DTU Space in a small Compton camera payload, with the primary objective of technology demonstration. We have defined a scalable mass model for the payload, comprising eight 3D CZT drift strip detectors surrounded by CsI scintillator detectors for active shielding. The payload's angular resolution, effective area, and efficiency are evaluated through simulations of far-field monochromatic point sources. The instrument's sensitivity is assessed in a low Earth orbit background environment for nuclear line and continuum emission sources. With a 3σ point source sensitivity in the order of 10 -4 [ph/cm 2 /s], it is evident that such an instrument only allows for limited scientific goals. In-orbit simulations of bright sources are conducted, resulting in reasonable observation times for the Crab Nebula at a 5σ significance level. Furthermore, in-orbit simulations of a selection of bright gamma-ray bursts indicate the potential for observing bright transient events. The study underscores the potential of using 3D CZT drift strip detectors in Compton camera configurations but also highlights the need for a larger effective area to improve sensitivity. However, for a technology demonstration aimed at increasing the Technology Readiness Level of the 3D CZT drift strip detector, a small Compton camera configuration like the one presented in this study could be a viable solution.
instruments & instrumentation
What problem does this paper attempt to address?
The paper attempts to address the feasibility of using 3D CZT drift strip detectors to construct a small Compton camera for small space missions. Specifically, the study aims to evaluate the performance of this detector technology in the context of the Low Earth Orbit (LEO) background environment, including its angular resolution, effective area, efficiency, and sensitivity to nuclear line and continuum sources. Additionally, the research explores the potential of this small Compton camera configuration to enhance the Technology Readiness Level (TRL) of 3D CZT drift strip detector technology, particularly through a technology demonstration mission. The paper assesses the effectiveness and potential applications of the small Compton camera by simulating the instrument's performance with far-field monochromatic point sources and the Low Earth Orbit background environment. The results indicate that although the instrument's sensitivity is limited due to its small effective area and high background rate, it is still possible to achieve some limited scientific objectives, such as observing bright sources like the Crab Nebula and transient events like gamma-ray bursts. This provides a foundation for further optimization and expansion of the technology's applications in the future.