Optimization Analysis on Electrical Insulation Performance of ITER Axial Composite Insulation Break

Yun-Lai Qiu,Chang-Chun Yang
DOI: https://doi.org/10.2991/icmsa-15.2015.150
2014-01-01
Abstract:Optimization analysis on Electrical Insulation Performance was conducted using ANSYS soft for ITER axial insulation breaks. The optimal parameters of Li, and R have been achieved. The analysis results showed that the value of the maximal electric field in GFRP section is 3.396kV/mm. This position locates on the arc top of the interface between SS electrode...