Behaviour of Slender Square Concrete-Filled Stainless Steel Columns Subject to Axial Load

B. Uy,Z. Tao,Fei-Yu Liao,Lin-Hai Han
2009-01-01
Abstract:Due to its excellent corrosion resistance, decorative qualities, ease of mainte- nance and fire resistance, the past few decades have seen the accelerating interest in the use of stainless steel in construction throughout the world. Concrete-filled steel tubular columns comprised of stainless steel ideally combines the advantages of both stainless steel and con- crete. So far, research on the concrete-filled stainless steel tubular (CFSST) columns is still quite limited, and mainly focused on short columns. In practice, columns are usually sub- jected to the influence of slenderness. A total of 6 square CFSST columns were tested under axial loading conditions to evaluate the influence of global slenderness. Several existing de- sign codes, including the Australian design code AS 5100 (2004), American code AISC (2005), Chinese code DBJ 13-51-2003 (2003) and Eurocode 4 (2004), are used to predict the column strength and are compared with the test results. This is helpful in evaluating the appli- cability of the current codes in calculating the strength of slender CFSST columns.
What problem does this paper attempt to address?