Behavior of Eccentrically Loaded Large-Scale CFST Slender Columns with Latticed Annular Steel

Zi-Ming Yang,Ju Chen
DOI: https://doi.org/10.1016/j.istruc.2024.107451
IF: 4.1
2024-01-01
Structures
Abstract:The eccentric compressive performance of circular CFST columns with latticed annular steel was studied through eccentric loading tests on three specimens with a slenderness ratio of 48. The Finite Element (FE) analysis, incorporating boundary conditions and material constitutive models consistent with the experimental setup, exhibited a high degree of concordance with the experimental findings. The validated FE model comprehensively investigated the confine effect of latticed annular steel on core concrete under eccentric compression, while also exploring the influence of different configurations of embedded steel skeletons on composite columns. Furthermore, it assessed and quantified the effects of the confinement factor of the steel tube, reinforcement ratio of the latticed annular steel, and slenderness ratio (lambda) on the ultimate bearing capacity of this composite structure at different load eccentricities ratio (e0/r). The relationship between balance eccentricity ratio and confinement factor has been established. By comparing the axial force-bending (Nu-Mu) interaction diagrams generated by different design rules, it is observed that the formulas in AISC 360-10 and Eurocode 4 tend to exhibit a conservative approach, while the formulas in DL/T 5629-2021 demonstrate a lack of conservatism. Finally, a proposal for a set of trilinear Nu-Mu interaction equations is made, which can yield more accurate results.
What problem does this paper attempt to address?