Analysis of High Temperature Flange & Bolt Temperature Variation of the Steam Turbine Cylinder During Start-Up Process Based on In-Service Data

Ming Kang,Geng-Hui Jiang,Shi-Fang Wu,Wei-Zhe Wang
DOI: https://doi.org/10.33737/gpps23-tc-084
2023-01-01
Abstract:In order to monitor the temperature and temperature difference levels of the flange-bolt components in the cylinder's joint surface during start-up process, temperature measurement elements are installed at different depths of the flange and at different heights of the bolt. The temperature of each measurement point and the temperature difference between the measurement points are analyzed in the cold start, warm start and hot start modes with the unit in-service data. The maximum temperature difference between the flange-bolt, between different depths of the flange and between different heights of the bolt in the warm start mode is higher than the maximum temperature difference values corresponding to the cold start and the hot start mode, which corresponds to a maximum temperature difference of 110 °C between the flange and the bolt, 70 °C between different depths of the flange and 28 °C between different heights of the bolt. The results of the study are important for understanding the temperature change pattern of the flange-bolt structure system of the cylinder during the start-up phase, and also provide guidance for its structural strength assessment and high temperature creep fatigue life assessment.