Key Question of Evaporative Cooling for Large Hydrogenerator--Comparison and Correctional Recommendation of Amplificatory Multiple Oftwo-Phase Flow Frictional Resistance Inside the Stator’s Hollow Conductor S

Xinliang Tian
2004-01-01
Abstract:Successful operation of 400MW evaporative cooling hydrogenerator indi cated this technique stepping into the large capacity stage. In order to further advance the capacity of hydrogenerators, the key point of evaporative cooling t echnique-calculation of two-phase flow should be more accurately grasped, espe c ially the determination of the multiple of two-phase flow frictional resistance . This paper compared three kind of calculative methods of amplificatory multiple of two-phase flow frictional resistance by selecting rectangular hollow conduc t or with inner size of 2.5×9.6 as investigative object and by using simulative c o mputation and model experiment as investigative methods,and finally make correc tion to Friedel . [1]. method.Correctional result showed that the maximum error betw een computing flux and measured flux by experiment was less than 10 percent. Thi s manifested corrected Friedel method is reasonable and can be used to the calcu lation of evaporative cooling circulating system of large capacity hydrogenerato rs.
What problem does this paper attempt to address?