Density Distribution in the Furnace in 75 T/h CFB Boiler with Water Cooled Square Separator

Jiansheng Zhang
1998-01-01
Abstract:Measurement of solid suspension density distribution in the furnace of a 75t/h circulating fluidized bed boiler (CFB) with the water cooled square separator was conducted with the probe developed by Tsinghua University. Local solid suspension densities along the height and the depth of the furnace were measured respectively. The measurement results are analyzed and the density distribution along the height and cross section are determined. According to the measurement data, a calculation model to estimate the local solid concentration is developed. This model will be used for scaling up design of the circulating fluidized bed boiler.
What problem does this paper attempt to address?