Measurement of particle density distribution near water wall of a 330 MW unit CFB boiler

Xinglong ZHOU,Jianwen XIE,Yongshen FAN,Leming CHENG,Kefa CEN,Shengbin GAO
DOI: https://doi.org/10.3969/j.issn.1002-3364.2015.01.039
2015-01-01
Abstract:The solid particle concentration in furnace of the CFB boiler has great influence on water wall heat transfer,furnace temperature distribution and heating surface abrasion.Measuring holes were set on water walls of a subcritical 330 MW unit CFB boiler.A drawer-style device is used to detect the local parti-cle concentration in the furnace,thus to investigate the horizontal distribution of particle concentration near the water wall.The results show that,within a 1 m radius to the water wall,the particle concentration de-creases with the increasing distance to the water wall,and the particle concentration remains stable in the core region at the same height.The higher the measuring holes,the lower the particle concentration.A rise in the superficial gas velocity increases the particle concentration in the upper section of furnace.A corre-late equation of the horizontal distribution of particle concentration near the water wall is fitted with the experimental results.The calculation error of this equation is less than 20%.
What problem does this paper attempt to address?