Closed-loop Micro-Accelerometer Based on Capacitive Sensing Interface ASIC

Jingxin Dong
2012-01-01
Abstract:The parasitic capacitor is one of the most important elements for the capacitive micro-accelerometer that adopts a two-chip approach combining micro-sensor and interface ASIC.A capacitive sensing interface ASIC with parasitic-insensitive and sample-charge architecture is designed,and implemented in a standard 0.35-μm CMOS process.Based on the sensing interface ASIC,an accelerometer prototype with multi-finger micro-machined sensor is designed,in which force-rebalance with the lag-proportional-integral(PI) controller is applied to implement the closed-loop system.The testing results indicate that the sensitivity and the noise floor of the presented accelerometer is 650 mV/g and 23.17μg/(Hz)~(1/2),respectively.
What problem does this paper attempt to address?