Evaluation of Thermodynamic State of Rotor Under In-Service Operating Conditions

CAI Zhenwei,HONG Hui,WANG Weizhe
DOI: https://doi.org/10.13707/j.cnki.31-1922/th.2022.03.005
2022-01-01
Abstract:It is difficult to evaluate the thermal state of turbine rotor because of the various load types and processes in the actual operating conditions of thermal power plant. Based on the decommissioned turbine rotor as the research objective, combining with the working condition of the rotor with a history of nearly 10 years running, the finite element simulation towards the whole history was calculated. The temperature and stress behaviors of the rotor under start-stop and down-output conditions were emphatically studied. The results displayed the variation range of the steam inlet position and the temperature and stress in the groove before the high pressure stage under the condition of power reduction. When the power reduction exceeded 100 MW, the maximum value of the temperature range reached 51 ℃ at steam inlet position, while the stress range was 165 MPa, thus the induced fatigue damage needs to be considered. The research result can provide reference for the structure design and operation management of high-and intermediate-pressure rotors.