Abstract:In order to have exact foundation in the decision of the danger point of steam turbine rotor in linear thermal-stress inspection and life-span management system,calculation of finite number of elements of thermal-stress coupled-field for 135 MW steam turbine rotor under the cold starting-up condition was calculated.The temperature and stress distribution of two different rotor model with and without central hole were calculated,with the same geometrical dimension,same boundary conditions and same initial conditions.The result shows that the two rotor models do not have great difference in the stress of outer surface,but have great difference in the stress of central position.