Accurate mechanical-optical theoretical model of cross-axis sensitivity of an interferometric micro-optomechanical accelerometer

Weidong Fang,Qixuan Zhu,Jian Bai,Jiaxiao Chen,Xiang Xv,Chen Wang,Qianbo Lu
DOI: https://doi.org/10.1364/AO.447762
IF: 1.9
2022-01-01
Applied Optics
Abstract:An interferometric micro-optomechanical accelerometer usually has ultrahigh sensitivity and accuracy. However, cross-axis interference inevitably degrades the performance, including its detection accuracy and output signal contrast. To accurately clarify the influence of cross-axis interference, a modified mechanical-optical theoretical model is established. The rotation of the proof mass and the detected light intensity are quantitatively investigated with a load of cross-axis acceleration. A simulation and experiment are performed to verify the correctness of the theoretical model when the cross-axis acceleration is from 0 to 0.175 g. The results demonstrate that this model has a more than fivefold accuracy increase compared with conventional theoretical models when the cross-axis acceleration is from 0.06 to 0.175 g. In addition, we provide a suppression method to diminish the rotation of the proof mass based on squeeze film air damping, which significantly suppresses the contrast reduction caused by crossaxis interference. (C) 2022 Optica Publishing Group
What problem does this paper attempt to address?