Experimental Study and Industrial Application of N-reagent Injection in Staged Flame for Denitration

De-Gui BI,Jian ZHANG,Zhong-Xiao ZHANG,Pu-Jie YUE,Yan-Yan RONG
2017-01-01
Abstract:Conventional Selective Non Catalyst Reduction (SNCR) is used for reduction NOx by injection N-reagent in flue gas which of temperature is 850~1100℃.SNCR application also could be extended to lower oxygen concentration and higher temperature condition,which is N-reagent Injection in Staged Flame (NISF).In this paper,the influence factors of reduction NOx with NISF was studied by bench-sacle experiment,and industrial retrofit on a 75 t/h boiler.The results showed that the higher temperature the lower the NOx emission was when the Stoichiometric Ratio (SR)≤0.85,the reverse results was achieved when SR>0.85.Denitration effect was better when lower SR was given,NOx emission was higher with increase the quantity flow of ammonia when SR>0.95.The optimum Normalized Stoichiometric Ratio (NSR) was decreased as the excess air coefficient decreased.The test about NISF application in a retrofitted boiler was done,the optimum injection location was the corners of the furnance,NOx emission of 390 mg/m3 was achieved when OFA was adopted only,while 138 mg/m3 with OFA and SNCR.on this basis,NOx emission of 84 mg/m3 was got with NISF application,denitration efficiency was increased by 15.46%,and no ammonia slip.