NOx Reduction by Aqua Ammonia Injection at 2.11 MW Tangential Pulverized Fired Boiler

ZHOU Jun-hu,LU Zhi-min,WANG Zhi-hua,YANG Wei-juan,ZHANG Yan-wei,CEN Ke-fa
DOI: https://doi.org/10.3785/j.issn.1008-973x.2006.06.009
2006-01-01
Abstract:To study influences of different factors on the NO_x reduction in pulverized coal fired boiler,an NO_x selective non-catalytic reduction(SNCR) experiment was carried out at a 2.11 MW pilot scale foursquare tangential pulverized coal fired boiler.Aqua ammonia with different flow rate was injected into the furnace at different temperature locations by different mechanical atomizers.The results indicate that normalized stoichiometric ratio(NSR) of ammonia to nitrogen oxides and the aqua ammonia injection temperature are critical for NO_x reduction.NO_x is reduced from uncontrolled 807 mg/m~3 to 164 mg/m~3,and NO_x reduction of 80% is achieved with NSR equal to 3.0.NO_x reduction increases with temperature decreasing from 931~1 057 ℃.The mixing effect of the aqua ammonia droplets and the effluent is critical for NO_x reduction,and the reduction of NO_x is doubled by using a flat sector sprayer compared to using a conical sprayer.