Full-Scale Numerical Investigation of a Selective Noncatalytic Reduction (SNCR) System in a 100 MW Utility Boiler with Complex Chemistry and Decoupling Approach
Yu Lv,Zhihua Wang,Junhu Zhou,Kefa Cen
DOI: https://doi.org/10.1021/ef100712e
IF: 4.6541
2010-01-01
Energy & Fuels
Abstract:To efficiently model the selective noncatalytic reduction (SNCR) process in a larger utility boiler, a decoupling numerical simulation approach, to separately treat coal combustion and SNCR NOx reduction in the furnace, was presented in this study. The simulated boiler has a full capacity of 100 MW, and the SNCR system is installed at the height of the furnace arch, mainly including groups of reagent nozzles. Urea solution was used as a reactive reagent, so that a relatively complex chemistry, along with the eddy dissipation concept (EDC) model, was introduced to accurately mimic the NOxOUT process in turbulent flow. Simulations are validated with experimental measurements. The reaction temperature, reagent amount, and reagent droplet momentum effects on the SNCR performance, primarily NOx removal and NH3 slip, were investigated in detail. The results show that, only at certain temperature regions. NOx removal gives a continuous rise with the increase of the reagent amount but commonly with a more serious NH3 slip; increasing reagent droplet momentum can be an available technique to enhance the poor global mixing between reagent droplets and flue gas in such a large furnace space. In addition, an empirical optimization of the simulated SNCR system was conducted, and potential methods to benefit SNCR system design and operation were demonstrated, such as multi-level nozzle arrangement and the application of flat atomizers.