Numerical study of mixing characteristic between flue and droplet at 410t/h coal-fired boiler SNCR system

z wang,l yu,p he,w yang,j zhou,k cen
2009-01-01
Abstract:Numerical study of the mixing process between urea solution droplet and flue gas at 410 t/h coal-fired boiler selective non-catalytic reduction(SNCR) system was conducted based on Fluent platform, meanwhile the effect of this mixing characteristic on NOx removal efficiency was discussed. It is found that the droplet penetration length that is dependent on the liquid flow and droplet size for a given nozzle has great influence on the mixing between gas and liquid in large space, and on the NOx removal efficiency. However, due to the temperature gradient existing along the injecting direction, NOx removal efficiency also depends on the local temperature at which droplets distributed. The simulation results show that at fixed molar ratio of NH3/NO, NOx removal efficiency can improve 8.8% with the 82% increase of injection flow, and as droplet size rises it represents increasing tend followed by a slight fall. In addition, the calculation result was compared with the experimental data measured, to guarantee the reliability of the conclusion drawn from this numerical study.