Experimental study on reducing NOx emission ofanthracite with rich reagent injection

纪新强,张忠孝,毕德贵,付振华
DOI: https://doi.org/10.16189/j.cnki.nygc.2017.02.010
2017-01-01
Energy Engineering
Abstract:Experimental study was carried out on the one-dimensional electric heating drop-tube furnace for Rich Reagent injection, injecting ammonia in the primary zone to reduce NOx based on the air classification.The study found that, the primary zone excess air coefficient SR,primary zone temperature T,nitrgen stoichiometric ratio NSR had important influence on the denitration efficiency.The smaller of the primary zone excess air coefficient SR,the higher of the denitration efficiency.The denitration efficiency could not be enhanced obviously by injecting ammonia,while the primary zone excess air coefficient was 0.75.Under the condition of T=1100℃,when the primary zone excess air coefficient SR =0.95 and 0.90, the denitration efficiency could be enhanced about 20%.In a certain range of excess air coefficient SR, the higher the temperature, the higher the denitration efficiency.But the high temperature was unfavorable to the ammonia injection,while the primary zone excess air coefficient was large.In most of the experimental conditions, the best denitration efficiency could be achieved when the NSR was between 1.5 and 2.0.
What problem does this paper attempt to address?