Abstract:The disfribution of composition and microstructure of the AIN/TiN layer of aluminum alloy 2024 im-planted by Plasma Based Ion Implantation(PBⅡ) were characterized using X -ray Photoelectron Spectroscopy(XPS) and Glancing Angle X -ray Diffraction (GAXRD). XPS results show that N and Ti can be implantedinto 2024 effectively, the content of N presents a Gaussian - like distribution, and that of Ti decreases gradu-ally along the implanted direction from the surface. The post -implanted elements have great influence on thecontent and depth profile of the pre - implanted ones. The simultaneously implanted Ti and N can form asteady layer of Ti and N on the surface. In comparison with 2024, the AIN/TiN layer has remarkably improvedthe mechanical properties, of which both the nano - hardness and the load bearing capacity have in most cases increased over 5 times, the friction coefficient has been decreased more than 70% , wear life has been im-proved near to 6 times, and the wear resistance has enhanced approximately 10 times and the degree of adhe-sive wear has lightened markedly at low sliding loads. Nevertheless, the wear-resistant properties are reducedgradually with increasing the sliding load. The great improvement of the mechanical properties is mainly owingto the proper structure of the layer and the presence of TiO2, TiN, TiAl3, Al2O3, and AIN phases in it.
What problem does this paper attempt to address?