Practice and optimization of combined pipe-blowing method for domestic first double-reheat unit

Jinghui GAO,Lin WANG,Bo YANG,Yafu ZHANG,Zhidan ZHAO,Hongyu WANG,Yingqi MENG
DOI: https://doi.org/10.3969/j.issn.1002-3364.2017.08.107
2017-01-01
Abstract:To explore suitable pipe-blowing methods for ultra supercritical double-reheat units, a decompression combined pipe-blowing method was proposed and put into practice on the domestic first double-reheat boiler. This new method is a combination of "one section pipe-blowing" method's structure and "two-section pipe-blowing" method's operating characteristics. The superheater, primary reheater, secondary reheater and its associated pipelines were connected in series in one time. The whole system is divided into three parts, and each part is purged and targeted separately. For the problem that the steam purge coefficient does not satisfy the standard, field test and theoretical analysis were carried out. Some measures, such as increasing the separator outlet steam pressure, opening multiple valves simultaneously, were taken into practice to eliminate the blocking flow effect and guarantee the purging quality. The final target plate tests results show that, the depression combined pipe-blowing method completed the purging of double-reheat boiler heating surfaces with high quality. This method can provide practical reference for other similar units.
What problem does this paper attempt to address?