Abstract:Studies on flue gas particles of various sizes, passing with different velocities through bundles of smooth tubes in aligned arrnagement, with different tube diameters and different pitches, both lengthwise as well as crosswise, have been conducted. Rules that govern the movement of flue gas gas particles, crossing bundles of smooth tubes in aligned arrangement, were obtained by numerical calculation, and a mathematical model of the passage rate of flue gas particles elaborated, which may serve as a guide, during design, for mitigating wear of horizontal air preheaters, superheaters, reheaters and economizers with aligned tube arrangement, placed in the rear part of circulating fluidized bed boilers. Figs 6, table 1 and refs 2.