Flow Behavior of High-Temperature Flue Gas in the Heat Transfer Chamber of a Pilot-Scale Coal-Water Slurry Combustion Furnace

Yanwei Zhang,Yu Bo,Yingchun Wu,Xuecheng Wu,Zhenyu Huang,Junhu Zhou,Kefa Cen
DOI: https://doi.org/10.1016/j.partic.2013.07.007
2014-01-01
Abstract:The flow characteristics of high-temperature flue gas are important in the heat transfer of coal-water slurry (CWS) combustion furnaces. The flow field of a 250 kg/h vertical-type slag tap cyclone furnace was non-intrusively investigated, using two-dimensional particle-image velocimetry (2D PIV). The method was verified using traceable fly ash particles in high-temperature flue gas. The flow field of the flue gas was analyzed with a time-averaged method, based on which the effects of excess air ratio and loading were investigated. The flue gas separated by a gas separator maintained good rigidity near the furnace wall, rather than eroding the heating surface. Numerical simulations validated the reliability of Ply under the actual circumstances within the furnace. This study provides guidelines for applying 2D PIV in analyzing flue gas in thermal test boilers. (C) 2013 Chinese Society of Particuology and Institute of Process Engineering, Chinese Academy of Sciences. Published by Elsevier B.V. All rights reserved.
What problem does this paper attempt to address?