Fault Tree Analysis of ITER VV Pressure Suppression System

Da-gui WANG,Jie WU,Hai-xia WANG,Run YUAN,Ming SUN,Zhi-bin CHEN
DOI: https://doi.org/10.3969/j.issn.0258-0918.2018.03.008
IF: 1.2
2018-01-01
Nuclear Science and Engineering
Abstract:Fusion power is the most promising clean energy in the future. The International Thermonuclear Experimental Reactor (ITER) program is one of the largest international cooperation scientific programs in the world, which will be the first fusion device to test the integrated technologies materials, and physics regimes necessary for the commercial production of fusion-based electricity. Vacuum Vessel (VV) houses the fusion reactions and acts as a first safety containment barrier. The Vacuum Vessel Pressure Suppression System (VVPSS) is designed to limit the VV internal pressure, as part of the first confinement barrier, which is classified as a safety important system. Based on the detailed design of VVPSS, the Fault Tree was established and the minimum cut sets were showed in this paper. Besides, the reliability of VVPSS was calculated. Those work lay the foundation for the ITER probability safety assessment.
What problem does this paper attempt to address?