Experimental study on C80 high strength pumped concrete

Qingxin FAN,Zhiyun YAO,Zhene JIAN,Dong LIN,Hengchang WANG
DOI: https://doi.org/10.3969/j.issn.1001-702X.2017.07.042
2017-01-01
Abstract:The effects of water-cement ratio,silicon content and slag content on the strength and pump ability of C80 high-strength pumped concrete are studied by orthogonal test. The results of orthogonal test showed that the order of influencing factors of 28 days strength of C80 concrete was silica fume content>slag content>water cement ratio,for pump ability,the test of slumping time showed that the influence of slag dosage was very significant,the ratio of water-cement was the second,and the influence of silica fume content on the slumping time was non-significant. On the basis of orthogonal test,the optimum mix proportion of C80 high strength pumping concrete was obtained:m(cement):m(sand):m(stone):m(silica fume):m(mineral powder):m(water reducing):m(water)=450:739:1006:30:120:13.2:144. The test results show that the concrete strength is 96 MPa in 28 d,reaches the design requirements of C80 concrete. Concrete initial slump is between 200~220 mm,and the slump loss is within 20 mm in 2 h,fresh concrete collapsed to fall cone time less than 10 s,with low viscosity,good pump ability.
What problem does this paper attempt to address?