Effect of Water Mist on Hazardous Characteristic Parameters of Fire Smoke in Subway Station Hall

Yan FAN,Xuefeng HAN,Juncheng JIANG
DOI: https://doi.org/10.16037/j.1007-869x.2017.11.010
2017-01-01
Abstract:Aiming at the characteristics of subway station hall fire and under the natural ventilation,subway station fire is simulated in the condition of water mist and the condition without water mist separately.The variation of hazardous characteristic parameters,including fire temperature,the mole fraction of CO2,CO and O2,and the changes of SI (safety index) are obtained.The collected data show that the effect of water mist in reducing the mole fraction of CO2 and O2 is obvious,that will help passengers in safety evacuation.
What problem does this paper attempt to address?