Optimization of Ventilation Mode During Intermediate-Floor Fire in a Typical Multi-Floor Subway Station

纪杰,钟委,张英,霍然
2010-01-01
Abstract:Taking a typical cross-type transfer subway station with 3 floors as the research object, based on the investigation and analysis for combustibles in the subway station, a fire source was designed following t~2- curve with a peak heat release rate of 2MW. In terms of the station structure, the smoke zone partition in public area and the ventilation system configuration of each floor, two types of fire emergency ventilation mode were selected, which were the modes with and without operating the air supply system in the floor below the fire floor. Using the computational fluid dynamics software FDS5. 0, a 3D model of the subway station was built with a fire located much close to one end wall in the second floor. Large Eddy Simulation model was used to assess the effect of the mechanical smoke exhausting of the fire floor under different ventilation modes. The analysis of the flow field, temperature field and velocity field in the fire floor showed that once the air supply system in the third floor was operated, the amount of air supplied to the fire floor and the pressure in the fire floor increased, the depth of smoke layer and the temperature in the smoke zone where the fire occurred was effectively reduced. Therefore, a more effective smoke control was obtained.