Numerical simulation of smoke control modes in underground railway station fire

Zhou Ru,He Jiapeng,Jiang Juncheng
DOI: https://doi.org/10.3969/j.issn.1002-8501.2007.09.008
2007-01-01
Abstract:Puts forward a smoke control mode of applying smoke-preventing air curtain substituting for ceiling screen and down air flow with velocity no lower than 1.5 m/s at the landing of stairs.Establishes a physical model of a two-layer underground railway station,simulates and compares four smoke control modes by CFD.The results indicate that more than 6 minutes for safe evacuation can be guaranteed by the smoke-prevention air curtain and the quantity of fresh air is reduced compared with the conventional modes,therefore effectively prevents the fire expanding further and controls the smoke spreading.