Simulation of Smoke Movement and Ventilation in Fire at Island-platform of Deep Buried Metro Station

SHI Cong-ling,ZHONG Mao-hua,TU Xu-wei,DENG Yun-feng,FU Tai-ran,HE Li
DOI: https://doi.org/10.3969/j.issn.1003-3033.2006.03.004
2006-01-01
Abstract:With the development of subway in China, most stations in megalopolis area will be built by deep embedment technology, especially for the lines passing through old downtown with lots of building piles underneath. So fire safety in these metro stations should be deeply concerned and further studied. By CFD simulation, horizontal movement of smoke at island platform and vertical diffusion of smoke at different level of the platform are studied. Distribution of characteristic parameters such as smoke temperature, concentration of toxic gases and visibility during the smoke diffusing through the tunnel, platform and waiting hall is analyzed. The efficient air flow and ventilation pattern and tunnel effluent system are explored. The results might be beneficial to the ventilation design and safety management for similar subway station.