Influence of Protective Grounding on High-speed EMU Grounding Reflux

WEI Xiaobin,GAO Guoqiang,CHEN Pan,WU Guangning
DOI: https://doi.org/10.3969/j.issn.1001-8360.2017.08.006
2017-01-01
Abstract:The pros and cons of protective grounding methods are related to the running performance of the EMU directly.Given no unified choice of protective grounding modes both at home and abroad, the study on protective grounding is of great significance.Among the protective grounding modes, the concentrated protective grounding does not ensure zero of the car body potential, while the scattered protective grounding has a problem of reflux.This paper analyzed the mechanism of the disadvantages of the concentrated protective grounding, and established the vehicle grounding reflux model of the scattered protective grounding by the PSPICE software.Combined with the actual test results, this paper analyzed the distribution regularity of protective grounding reflux, and finally improved the scattered protective grounding by eliminating current loop.The simulation results show that current loop between the bogies is the main reason for the increase of grounding current.The improved grounding method reduces the shaft end potential to 0.2 V.The protective grounding current value is less than 20 A with uniform distribution.
What problem does this paper attempt to address?