Abstract:The effect of discharge gap on discharge characteristics of DBD and H 2 S removal were focused on.Also,the influence of inlet concentration ,humidity,residence time and peak voltage on the removal rate of H2 S were investigated .The results showed that when the discharge gap decreased ,the starting volt-age of the reactor discharge decreased and the more ozone was yielded;correspondingly ,the removal rate of H2 S increased.Decreasing H2 S inlet concentration and increasing residence time would increase the removal rate of H2 S.At a lower peak voltage ( less than 7 kV) ,H2 S was not removed at a high humidity . However,at a higher peak voltage ,the optimal humidity value for H 2 S removal was 17.5%.