Study on ozone generation from H2S and NH3 removal by pulsed corona discharge

Jianjun Ruan,Yao Shi,Wei L. Pan
2006-01-01
Abstract:The pulsed corona discharge process was applied for the removal of H2S and NH3 from the simulated odors in a wire-plate corona reactor. O3 generation was investigated in their removal processes, respectively. The concentration of O3 increased with the specific energy density. In the case of H2S removal with the initial concentration of 200 mg/m3 and the gas-flow rate of 23.0 m3/h, the concentration of O3 was about 150 ppm in the specific energy density of 13.2 W h/m3. Compared to the corona discharge in air, it decreased. While whether NH3 existed in air or not, the concentration of O3 was almost the same and it was about 200 ppm in the specific energy density of 16.1 W h/m3. The results indicate that H2S may react with O3 and NH3 cannot be oxidized by O3.
What problem does this paper attempt to address?