Effect of Operation Modes on Hydrodynamic Performance of Pilot-Scale Pulsed Disc-and-Doughnut and Pulsed Sieve-Plate Columns: A Comparative Study

Xiong Yu,Han Zhou,Qiang Zheng,Shan Jing,Wenjie Lan,Shaowei Li
DOI: https://doi.org/10.1080/07366299.2020.1765507
2020-01-01
Solvent Extraction and Ion Exchange
Abstract:This work presented hydrodynamic performance of pilot-scale pulsed sieve-plate column (PSPC) and pulsed disc-and-doughnut column (PDDC) in different operation modes for the uranyl nitrate/30% (v/v) tributyl phosphate in kerosene system. It was found that the hydrodynamic performance of PSPC and PDDC was similar in the aqueous continuous mode, in which the stainless-steel internal plates were not wettable to the dispersed phase. In the organic-continuous mode, more energy inputting was required to attain a similar dispersion efficiency than that in the aqueous continuous mode. Moreover, the liquid-liquid flow in PSPC exhibited poorer dispersion efficiency than that in PDDC and was easier to run into the flooding regime as the throughput was increased. Wettability of the stainless-steel internal plates and geometrical structure differences between the sieve plates and disc/doughnut plates were the main reasons for these phenomena. Correlations for the prediction of holdup in both PDDC and PSPC were proposed based on experimental results.