Effect of Sieve Plate Arrangement on Mass Transfer Performance of Pulsed-Sieve-Plate Extraction Column

唐晓津,骆广生,李洪波,汪家鼎
DOI: https://doi.org/10.3321/j.issn:1000-8144.2003.12.008
2003-01-01
Abstract:To study the effect of dispersion and coalescence on mass transfer performance in extraction columns, three types of sieve arrangement in a pulsed-sieve-plate extraction column (PSEC) were designed by inserting different number of dispersion and coalescence plates into the column. Characteristics of mass transfer and axial mixing were evaluated and compared using a working system of 30% tributylphosphate (TBP, in kerosene)/nitric acid/water. Thus, the mass transfer efficiency of dispersion-coalescence pulsed-sieve-plate extraction column (DCPSEC) could increase by > 30% as compared with standard PSEC, due to the influence of an interface renewal through an arrangement of 50 mm in plate spacing and one coalescence plate every four plates. Mass transfer efficiency of another type of DCPSEC with 25 mm in plate spacing was lower than that of standard PSEC because lowering plate spacing would lead to bad dispersibility and lower interface area, despite the fact that lowering of axial mixing was greater than that of the other two types of PSEC. Therefore, it is very important to optimize dispersion and coalescence conditions for better performance of columns.
What problem does this paper attempt to address?