RF AND PRIMARY BEAM DYNAMICS DESIGN OF A 325 MHz IH-DTL

R. Tang,S. Zheng,Q. Xing,Y. Lei,X. Guan,X. Wang,C. Tang
2017-01-01
Abstract:An interdigital H-mode drift tube linac (IH-DTL), which is aimed at proton medical facilities, has been proposed and developing at Tsinghua University. Considering following 3 MeV RFQ in the platform of CPHS (Compact Pulse Hadron Source at Tsinghua University) and XiPAF (Xi`an Proton Application Facility) project, the input energy of IH-DTL is 3 MeV and the RF frequency is 325 MHz. The proton beam can be accelerated from 3 MeV to 7 MeV and the peak current of the beam at the exit of the cavity is about 15 mA. In order to simplify the fabrication, A KONUS structure without focusing element in the cavity is chosen. The RF design of single CELL and the primary dynamics design is done. The co-iteration of dynamics simulation and RF calculation of whole cavity is undergoing. INTRODUCTION Facilities used for proton and carbon therapy become more and more popular. IH DTL has been used widely in the injector of clinical synchrotrons because of its high RF power efficiency at low beam velocity (beta<0.1) [1]. A 216 MHz IH-DTL has been developed for HICAT (Heidelberg Heavy Ion CAncer Therapy) project [2]. There are 4 KONUS (Kombinierte Null Grad Struktur) sections and three triplets in the tank. The proton beam can be accelerated from 0.4 MeV to 7 MeV in 3.76 m. The high effective gradient is 5.5 MV/m [3]. Another kind of proton IH DTL is developed via APF (Alternating Phase Focusing) beam dynamics. The length of this cavity is ~1.7 m. It can accelerate 10mA proton beam to 7.4 MeV at 200 MHz [4]. Those two kind of beam dynamics are both applied in IH cavity widely. Considering the platform of CPHS (Compact Pulse Hadron Source at Tsinghua University) and XiPAF (Xi`an Proton Application Facility) project, a 325 MHz IH-DTL is proposed and developing. The main parameters of this linac is shown in Table1. In order to simplify the fabrication, there is no focusing elements in the cavity. That makes the need of short length and high effective gradient. The total length of this IH-DTL is less than 1.2 m. That motivates the optimization of single cell geometry to get high acceleration gradient and high shunt impedance. The design and optimization process of single cell is described in the 2 section. Almost all the KONUS dynamics design is done by LORASR code (LOngitudinale und RAdiale Strahldynamikrechnungen mit Raumladung). A new and simple Matlab code has been developed to produce the primary structure of an IH-DTL with KONUS lattice. The process of code development and primary design results are described in the 3 section. Table 1: Parameters of 325 MHz IH-DTL
What problem does this paper attempt to address?